To change the FoV, there are 3 major topics to consider:

a. New lens: a lens with the adjusted Field-of-View FoV needs to be applied.

b. New VCSEL laser: the Field-of-Illumination (FoI) of the VCSEL laser needs to be adjusted to the changed FoV of the lens.

c. Depending on the opening angle, the 3D calibration needs to be modified.

With a change of the FoI, laser safety needs to be re-assessed.

In case of reasonable volumes, we are happy to support. Please feel free to come back to us.